used chlordioxyd plant for disinfectant production

description: Chlordioxyd elektrytical plant for bewerage industry.

Producer:Fumatech
Typ:ECA 30 LSCH, MUNK E230 G50/60 WRG-TFMX
Year of manufacture:2009
Pieces:1



technical data

Description  (Disinfection plant Fumagen - 30-LSHC. The system is designed in an open frame construction. Plant for electrochemical production of disinfection and membrane electrolysis.)
Power  (Evaluation of plant performance during automatic operations)
Voltage  25 A (per electrolysis)
Voltage  9 V (per cell (displayed voltage 18.3 V))
Volume flow rate  200 l/h (Volume flow anolyte)
Volume flow rate  30 l/h (Volume flow catholyte)
Accessories  (Rectifier (MUNK E230 G50 / 60 WRG-TFMX))
(Evaluation device Hydrogen (Honeywell Zareba Touchpoint 1))
(Flushing valve air flushing / maintenance unit compressed air and automatic safety devices are contained in the control cabinet)
Accessories  (system components)
(2x electrolytic cell FTEC-500-LS)
(3x dosing pump BWT Medo II (max 12 l / h citric acid / max 8 l / h soda / max 12 l / h circulation catholyte))
(3x Grundfos centrifugal pump CR12-2 / max. 2.5 m³ / h (2x centrifugal pump electrolysis cell / 1x centrifugal pump suction brine tank))
(2x hydrogen destroyer hydrocat)
(1x cleaning chemical tank (membrane cleaner))
(Prefilter / pressure reducer / control valves / temperature monitoring and degasser Katholyt)
Dimensions  (total)
Length  2500 mm
Width  650 mm
Height  1750 mm
Accessories  (Pumps to anolyte tanks)
Delivery rate  54 l/h (Max. / Dosing pump Eldos EMP III)
Pressure  10 bar (max.)
Delivery rate  9.5 m³/h (max / Centrifugal Pump Prominent Type 1820 PVDF / FK1)
Lifting height  13 m (max.)
Power  1.1 kW
Accessories  (Centrifugal pump to catholyte container / Espa type Alfa 500M)
Delivery rate  3.1 m³/h (max.)
Lifting height  35 m (max.)
Power  0.6 kW
Accessories  (Control box for tank control of the ECA system (electrical cable connection not connected))


more info:
Alle Angaben, Bilder, Hinweise und Empfehlungen erfolgen nach bestem Wissen, je- doch ohne Gewähr. Änderungen der technischen Angaben bleiben vorbehalten.

Tipp Umwelt-
und Verfahrenstechnik GmbH
Obere Hilgenstock 34
D-34414 Warburg
Tel.: +49 5641 7447-0
Fax: +49 5641 7447-28


E-Mail: mail@tipp-international.de
Internet: www.tipp-international.de
   Tipp Umwelt- und Verfahrenstechnik GmbH - Obere Hilgenstock 34 -34414 Warburg - +49 (0) 5641/7447 - 0
Tipp Umwelt- und Verfahrenstechnik GmbH - Obere Hilgenstock 34 -34414 Warburg - +49 5641 74470
www.tipp-international.de